Heat pump defrost cycle: what is normal
Steam, a pause and a whoosh on a cold morning is usually a defrost cycle working. Here is what to watch for.
In heating mode the outdoor coil is colder than the surrounding air. On a cold, damp East Bay morning, moisture freezes onto that coil as frost. A thin layer of frost is normal; a thick layer blocks airflow and cuts heating, so the system periodically melts it off.
To do that, the heat pump briefly reverses into cooling mode, sending hot refrigerant to the outdoor coil while the outdoor fan stops. Indoors, the electric backup strips (or gas furnace on a dual-fuel system) may switch on to keep the air from feeling cool during that short break.
You may see a cloud of steam rising from the outdoor unit, hear a whoosh as the reversing valve switches, and notice the fan stop for a few minutes. Water drips from the unit as the ice melts. Most cycles last a few minutes and then heating resumes.
Cycles happen more often when it is cold and humid, and less often when the air is dry. Seeing one now and then in winter is a sign the system is doing its job.
A unit that stays encased in ice for hours, a defrost that never ends, ice that builds on the lower part of the coil and spreads upward, or a house that does not heat while the outdoor unit sits frozen are problems. Causes include a failed defrost sensor or board, a stuck reversing valve, low refrigerant charge, restricted airflow, or a blocked drain at the base of the unit.
Never chip ice off the coil with a tool; the fins and tubing are easy to damage. A gentle rinse of lukewarm water is the most you should do, and only after switching the system off.
Keep the area around the outdoor unit clear of leaves and debris, make sure the unit sits level and the base can drain, and keep the filter clean so indoor airflow is good. Do not cover a heat pump in winter, because it runs in winter.
If you are in doubt, note how long the ice has been there, whether heat is reaching the house, and any error code on the thermostat, and give us that when you call.
We watch a full defrost cycle, check sensors, charge and the reversing valve, and test the outdoor fan and controls before recommending a repair. Concord, Walnut Creek and Pleasanton homes see this regularly in cold snaps. OTTER HVAC is at 2939 Santos Ln, Walnut Creek, open 7am–5pm seven days a week. Diagnostic visits are a flat $69 and you approve any repair after the findings are written down. Call (650) 900-0440 or book online.
Related service: Heat Pump Repair. Book a $69 diagnostic or a free install estimate. Hours: 7:00am–5:00pm, seven days a week. Shop: 2939 Santos Ln, Walnut Creek, CA 94597.
Related: All HVAC guides · Heat Pump Repair · Pricing and $69 diagnostic · Contact OTTER HVAC
Frequently asked questions
Is steam coming off my heat pump normal?
Yes, usually. It is melting frost during a defrost cycle. Heat should resume within a few minutes.
How long should a defrost cycle last?
Typically a few minutes. If it runs far longer or the unit stays iced for hours, have it tested.
Can I chip the ice off my heat pump?
No. You can damage the coil. Switch the system off and use lukewarm water only, or call for a service visit.
Should I cover my heat pump for winter?
No. A heat pump runs in winter and needs airflow.